PART NUMBER : D131 & D132 Series
• APC type connector back reflection does not degrade with repeated mating.
• Outer Sheath is Low Smoke Zero Halogen or PVC
• G.652D, G.657A1, G.657A2
• Connectors Type – SC, LC, FC ( UPC/ APC Type)
• 25 Years System Warranty
• Length of Patch cords: 0.5m, 1m, 1.5m, 2m, 3m, 5m, 10m, 15m, 20m, 30m
• FO patch cord comes in Cable Diameter with either 1.5mm or 2.0mm or 3.0mm
Datasheet
Availability :The Fiber used in DME PROLINK’s Fiber Optic Patch cord, is made of pure silica and germanium doped silica. A UV curable acrylate material is applied over the Fiber Cladding as primary protective coating.
DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001.
The FO Simplex/Duplex Patch cord with APC connector at both ends have end faces with curve but are angled at an industry standard 8°. This maintains a tight connection, and it reduces back reflection to about -70 dB.
• IEC 60793-1: Optical Fiber Part 1: Generic Specification
• IEC 60793-2: Optical Fiber Part 2: Product Specification
• IEC 60794-2: Optical Fiber Cables Part 2 Indoor cables- Sectional Specification
• ITU-T G652: Characteristics of a Single-mode optical fiber and cable
• ITU-T G.655: Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable
• IEC 61300-1: Basic Test and Measurement procedures – Visual Examination
• IEC 61754: Fiber Optic Connector Interfaces – SC, LC and FC
• IEC 61300-3-6: Basic Test and Measurement procedures – Examinations and Measurements – Return loss
• IEC 61300-3-34: Basic Test and Measurement procedures – Examinations and Measurements – Attenuation of random mated connectors
Tests | Criteria Data |
Appearance | Connector surface is smooth, no burr, no scratch, color uniformity. |
Insertion Loss | ≤ 0.3dB |
Return Loss | ≥65dB for APC |
Mechanical Durability | Plug and pull out for 1000 times, No scratch and meet optical performance |
Temperature Cycling | -40℃~85℃ 21 cycle 168 Hours ; ΔIL≤0.2dB,ΔRL<5dB, |
Fiber Type | Single mode | Single mode | Single mode | Single mode | Single mode | Single mode |
Connector Type | SC | LC | FC | SC | LC | FC |
Connector Surface | APC | APC | APC | UPC | UPC | UPC |
Insertion Loss (dB) | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 |
Return Loss (dB) | ≥ 65 | ≥ 65 | ≥ 65 | ≥ 55 | ≥ 55 | ≥ 55 |
Operating Temperature Range | ‐40°C to +85°C | |||||
Durability | > 1000 times | > 1000 times | > 1000 times | > 1000 times | > 1000 times | > 1000 times |
Standard | IEC 601754-4 | IEC 601754-20 | IEC 61754-13 | IEC 601754-04 | IEC 601754-20 | IEC 61754-13 |
The Fiber used in DME PROLINK’s Fiber Optic Patch cord, is made of pure silica and germanium doped silica. A UV curable acrylate material is applied over the Fiber Cladding as primary protective coating.
DME PROLINK quality personals ensures product reliability through rigorous qualification testing to assure cable performance and durability in adverse field environments. Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001.
The FO Simplex/Duplex Patch cord with APC connector at both ends have end faces with curve but are angled at an industry standard 8°. This maintains a tight connection, and it reduces back reflection to about -70 dB.
Fiber Type | Single mode | Single mode | Single mode | Single mode | Single mode | Single mode |
Connector Type | SC | LC | FC | SC | LC | FC |
Connector Surface | APC | APC | APC | UPC | UPC | UPC |
Insertion Loss (dB) | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 | ≤ 0.3 |
Return Loss (dB) | ≥ 65 | ≥ 65 | ≥ 65 | ≥ 55 | ≥ 55 | ≥ 55 |
Operating Temperature Range | ‐40°C to +85°C | |||||
Durability | > 1000 times | > 1000 times | > 1000 times | > 1000 times | > 1000 times | > 1000 times |
Standard | IEC 601754-4 | IEC 601754-20 | IEC 61754-13 | IEC 601754-04 | IEC 601754-20 | IEC 61754-13 |
• IEC 60793-1: Optical Fiber Part 1: Generic Specification
• IEC 60793-2: Optical Fiber Part 2: Product Specification
• IEC 60794-2: Optical Fiber Cables Part 2 Indoor cables- Sectional Specification
• ITU-T G652: Characteristics of a Single-mode optical fiber and cable
• ITU-T G.655: Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable
• IEC 61300-1: Basic Test and Measurement procedures – Visual Examination
• IEC 61754: Fiber Optic Connector Interfaces – SC, LC and FC
• IEC 61300-3-6: Basic Test and Measurement procedures – Examinations and Measurements – Return loss
• IEC 61300-3-34: Basic Test and Measurement procedures – Examinations and Measurements – Attenuation of random mated connectors
Tests | Criteria Data |
Appearance | Connector surface is smooth, no burr, no scratch, color uniformity. |
Insertion Loss | ≤ 0.3dB |
Return Loss | ≥65dB for APC |
Mechanical Durability | Plug and pull out for 1000 times, No scratch and meet optical performance |
Temperature Cycling | -40℃~85℃ 21 cycle 168 Hours ; ΔIL≤0.2dB,ΔRL<5dB, |
DME Prolink is the data communication division of ECS global Wire and Cable, that delivers high performance converged datacom solutions. We manufacture complete end-to-end intelligent structured cabling and data center solutions.
Introducing DME Prolink Patch Free FDH. Most ideal solution for connecting premises Fiber optic cables with Telco Fiber Access Network through inbuilt GPON Splitters. Approved by Etisalat. IN STOCK. #GPONSolutions #DMEProlink #FTTx
Electrical Cable Supply Ltd (DME PROLINK),
3135 – 6900 Graybar Road, Richmond,
BC V6W 0A5 Canada
Phone: +1 604 276 9913
Fax: +1 604 276 9915
ECS Global Wire & Cable FZCO (DME PROLINK),
Jebel Ali Free Zone, South Side,
PO Box. 17159, Dubai UAE
Phone: +971 4 811 8000
Fax: +971 4 880 9361