PART NUMBER : D093x-224TFPALB3PVGY
DME PROLINK 9841 RS485 Cable, 2 Conductor 24AWG (7 x 0.20) Stranded Tinned Copper, FPE Insulation, AL Foil with TC Drain wire + TC Braid (90%), PVC Outer Jacket, 305 meters, Grey
Datasheet
Availability : 100 Rolls in StockDME PROLINK 9841 RS 485 Cable, 2 Conductor (1 Pair) 24AWG (7 x 0.20) Stranded Tinned Copper, FPE Insulation, Overall Foil with Drain Wire + TC Braid (90%), PVC Outer Jacket
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
Conductor Diameter | 24 AWG (7 / 0.20) |
Conductor Material | Stranded Tinned Copper (TC) |
Conductor Dia. | Nom. 0.60 mm |
Conductor Count/ Total | No. of Pairs 2 / 1 |
Insulation Material | FPE |
Insulation Sheath Thickness | 0.59 mm |
Insulation Dia Nom. (± 0.05mm) | 1.78 mm |
st Shield Material | AL-Foil Overall Foil |
Drain / Structure Stranded | Tinned Copper / (7 / 0.20) |
nd Shield Material Tinned | Copper Braid (90% Coverage) |
Outer Sheath Material | PVC |
Outer Sheath Thickness | 0.90mm |
Cable Outer Dia Nom. (± 0.3mm) | 5.90 |
Insulation Colors | White-Blue / Blue-White |
Operating Temperature Range | ‐20°C to +80°C |
Max. Operating Voltage | 300V |
Packing Length (Meters) | 1000m / 305m / 152m |
Max. Conductor DC Resistance @20ºC (ohms/km) | 94.2 |
Impedance @ 1MHz (Ω) | 120 ± 20 |
Max. Attenuation @ 1 MHz (dB/100m) | 2.36 |
Nominal Velocity of Propagation (%) | 66 |
DME PROLINK 9841 RS 485 Cable, 2 Conductor (1 Pair) 24AWG (7 x 0.20) Stranded Tinned Copper, FPE Insulation, Overall Foil with Drain Wire + TC Braid (90%), PVC Outer Jacket
Conductor Diameter | 24 AWG (7 / 0.20) |
Conductor Material | Stranded Tinned Copper (TC) |
Conductor Dia. | Nom. 0.60 mm |
Conductor Count/ Total | No. of Pairs 2 / 1 |
Insulation Material | FPE |
Insulation Sheath Thickness | 0.59 mm |
Insulation Dia Nom. (± 0.05mm) | 1.78 mm |
st Shield Material | AL-Foil Overall Foil |
Drain / Structure Stranded | Tinned Copper / (7 / 0.20) |
nd Shield Material Tinned | Copper Braid (90% Coverage) |
Outer Sheath Material | PVC |
Outer Sheath Thickness | 0.90mm |
Cable Outer Dia Nom. (± 0.3mm) | 5.90 |
Insulation Colors | White-Blue / Blue-White |
Operating Temperature Range | ‐20°C to +80°C |
Max. Operating Voltage | 300V |
Packing Length (Meters) | 1000m / 305m / 152m |
Max. Conductor DC Resistance @20ºC (ohms/km) | 94.2 |
Impedance @ 1MHz (Ω) | 120 ± 20 |
Max. Attenuation @ 1 MHz (dB/100m) | 2.36 |
Nominal Velocity of Propagation (%) | 66 |
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
DME Prolink is the data communication division of ECS global Wire and Cable, that delivers high performance converged datacom solutions. We manufacture complete end-to-end intelligent structured cabling and data center solutions.
Electrical Cable Supply Ltd (DME PROLINK),
3135 – 6900 Graybar Road, Richmond,
BC V6W 0A5 Canada
Phone: +1 604 276 9913
Fax: +1 604 276 9915
ECS Global Wire & Cable FZCO (DME PROLINK),
Jebel Ali Free Zone, South Side,
PO Box. 17159, Dubai UAE
Phone: +971 4 811 8000
Fax: +971 4 880 9361
Introducing DME Prolink Patch Free FDH. Most ideal solution for connecting premises Fiber optic cables with Telco Fiber Access Network through inbuilt GPON Splitters. Approved by Etisalat. IN STOCK. #GPONSolutions #DMEProlink #FTTx